Compass Series Water-to-Water

Compass ws

GeoComfort single-stage water-to-water models are small in size and big on efficiency. These hydronic systems are designed to supply heated or chilled water for use in a wide range of heating and cooling applications, the most remarkable of which is radiant floor heating. This extremely comfortable heating solution warms your home from the floor up, allowing for constant and uniform heat distribution that eliminates hot and cold spots. The system is also reversible and capable of providing chilled water for air conditioning.


GeoComfort Limited Lifetime Warranty
Compass

Product Features

Available Literature

Product Brochure

EMGL0018 thumb

Owner's Manual

23230045001 thumb

Engineering Data & Installation Manual (WS)

20D150 01NN thumb

Engineering Data & Installation Manual (WD)

20D153 01NN thumb

Installation & Operation Manual - Rev. C

20D814 02NN thumb

Installation & Operation Manual - Rev. D

20D817 01NN thumb

Product Specifications

WS036

Cooling
Full BTU
34,700
EER
18.2
Part BTU
0
EER
0.0
Heating
Full BTU
26,600
COP
3.1
Part BTU
0
COP
0.0

WS048

Cooling
Full BTU
52,800
EER
17.7
Part BTU
0
EER
0.0
Heating
Full BTU
42,100
COP
3.1
Part BTU
0
COP
0.0

WS060

Cooling
Full BTU
60,000
EER
17.1
Part BTU
0
EER
0.0
Heating
Full BTU
53,000
COP
3.1
Part BTU
0
COP
0.0

WS072

Cooling
Full BTU
73,300
EER
17.7
Part BTU
0
EER
0.0
Heating
Full BTU
63,100
COP
3.4
Part BTU
0
COP
0.0

WS084

Cooling
Full BTU
83,600
EER
16.1
Part BTU
0
EER
0.0
Heating
Full BTU
74,200
COP
3.1
Part BTU
0
COP
0.0

WD120

Cooling
Full BTU
104,600
EER
14.5
Part BTU
63,500
EER
19.8
Heating
Full BTU
100,100
COP
2.8
Part BTU
57,500
COP
3.4

Available Accessories

"A" coil (hydronic)

The specially matched "A" coil allows the split geothermal system to be added to an existing air handler or furnace in retrofit applications. Additionally, the "A" coil can allow the system to operate in a dual-fuel application where backup heat is supplied by a traditional furnace.

Air handler (hydronic)

These multi-positional air handlers are specially matched to our split systems for maximum performance. The match also qualifies the system for the 30% U.S. federal tax credit. The air handler can be installed in remote parts of the home, or hard to reach areas where space is at a premium.

Programmable thermostat

Keeps the home more comfortable by operating the unit on a set schedule and temperature range. This also saves on energy costs by setting the unit back while the home is unoccupied.

Non-programmable thermostat

Designed to take maximum advantage of the multi-stage functionality of the unit. This allows the unit to achieve maximum savings by only operating at the right range to match the current weather.

Flow centers - pressurized

Circulates the fluid through the unit and the geothermal loop field. These types form a completely closed system.

Unit air pad (plastic or foam)

The unit air pad creates a buffer between the unit and the home. This buffer prevents any vibration from the unit to be transmitted into the home which improves the already quiet operation of the unit.

Consumer purchase plans

With a wide variety of payment options and terms, our consumer payment plans make installing a geothermal system easier and more cost effective. By deferring your initial payments out, you can start enjoying your new system earlier and take time to obtain many of the various rebates and tax credits offered.

Disposable pleated filter

This type of filter uses a pleated media to remove dust and other particles from the air stream. It is important to check these filters regularly and replace them as needed.

Electrostatic filter (washable)

This type of filter is a permanent media filter that can be washed from time to time as needed. This eliminates the need to buy new filters.

Electronic 24 volt air cleaner

This type of filter uses an electrically charged media to increase filtration performance. This improves indoor air quality by removing more particles from the airstream. This filter requires the occasional media replacement.

EWC zone control

These highly sophisticated controls work with dampers in the ductwork to create multiple zones throughout the house. You can utilize one unit, but have different temperatures in each zone. The control panel controls both the unit, and the zone dampers.

Flow center - non-pressurized

Circulates the fluid through the unit and the geothermal loop field. This type of system uses an expansion tank that can be topped off should the loop require it due to thermal expansion.

Auxiliary external electric heater

Adds that little bit of extra heat on those few coldest days. Also helps to balance the system size by balancing out those few extreme days. These heaters are installed in the supply air duct outside of the unit. Mostly used on horizontal style equipment.